FCC 17.253 Revised as of January 23, 2012
Goto Year:2011 |
2013
§ 15.253 Operation within the bands 46.7-46.9 GHz and 76.0-77.0 GHz.
(a) Operation within the bands 46.7-46.9 GHz and 76.0-77.0 GHz is
restricted to vehicle-mounted field disturbance sensors used as vehicle
radar systems. The transmission of additional information, such as
data, is permitted provided the primary mode of operation is as a
vehicle-mounted field disturbance sensor. Operation under the
provisions of this section is not permitted on aircraft or satellites.
(b) The radiated emission limits within the bands 46.7-46.9 GHz and
76.0-77.0 GHz are as follows:
(1) If the vehicle is not in motion, the power density of any emission
within the bands specified in this section shall not exceed 200 nW/cm^2
at a distance of 3 meters from the exterior surface of the radiating
structure.
(2) For forward-looking vehicle-mounted field disturbance sensors, if
the vehicle is in motion the power density of any emission within the
bands specified in this section shall not exceed 60 mW/cm^2 at a
distance of 3 meters from the exterior surface of the radiating
structure.
(3) For side-looking or rear-looking vehicle-mounted field disturbance
sensors, if the vehicle is in motion the power density of any emission
within the bands specified in this section shall not exceed 30 mW/cm^2
at a distance of 3 meters from the exterior surface of the radiating
structure.
(c) The power density of any emissions outside the operating band shall
consist solely of spurious emissions and shall not exceed the
following:
(1) Radiated emissions below 40 GHz shall not exceed the general limits
in § 15.209.
(2) Radiated emissions outside the operating band and between 40 GHz
and 200 GHz shall not exceed the following:
(i) For vehicle-mounted field disturbance sensors operating in the band
46.7-46.9 GHz: 2 pW/cm^2 at a distance of 3 meters from the exterior
surface of the radiating structure.
(ii) For forward-looking vehicle-mounted field disturbance sensors
operating in the band 76-77 GHz: 600 pW/cm^2 at a distance of 3 meters
from the exterior surface of the radiating structure.
(iii) For side-looking or rear-looking vehicle-mounted field
disturbance sensors operating in the band 76-77 GHz: 300 pW/cm^2 at a
distance of 3 meters from the exterior surface of the radiating
structure.
(3) For radiated emissions above 200 GHz from field disturbance sensors
operating in the 76-77 GHz band: the power density of any emission
shall not exceed 1000 pW/cm^2 at a distance of 3 meters from the
exterior surface of the radiating structure.
(4) For field disturbance sensors operating in the 76-77 GHz band, the
spectrum shall be investigated up to 231 GHz.
(d) The provisions in § 15.35 limiting peak emissions apply.
(e) Fundamental emissions must be contained within the frequency bands
specified in this section during all conditions of operation. Equipment
is presumed to operate over the temperature range -20 to +50 degrees
celsius with an input voltage variation of 85% to 115% of rated input
voltage, unless justification is presented to demonstrate otherwise.
(f) Regardless of the power density levels permitted under this
section, devices operating under the provisions of this section are
subject to the radiofrequency radiation exposure requirements specified
in § § 1.1307(b), 2.1091 and 2.1093 of this chapter, as appropriate.
Applications for equipment authorization of devices operating under
this section must contain a statement confirming compliance with these
requirements for both fundamental emissions and unwanted emissions.
Technical information showing the basis for this statement must be
submitted to the Commission upon request.
[ 61 FR 14503 , Apr. 2, 1996, as amended at 61 FR 41018 , Aug. 7, 1996; 63 FR 42279 , Aug. 7, 1998]
CiteFind - See documents on FCC website that
cite this rule
Want to support this service?