Goto Section: 73.210 | 73.212 | Table of Contents

FCC 73.211
Revised as of October 1, 2014
Goto Year:2013 | 2015
§ 73.211   Power and antenna height requirements.

   (a) Minimum requirements. (1) Except as provided in paragraphs (a)(3)
   and (b)(2) of this section, FM stations must operate with a minimum
   effective radiated power (ERP) as follows:

   (i) The minimum ERP for Class A stations is 0.1 kW.

   (ii) The ERP for Class B1 stations must exceed 6 kW.

   (iii) The ERP for Class B stations must exceed 25 kW.

   (iv) The ERP for Class C3 stations must exceed 6 kW.

   (v) The ERP for Class C2 stations must exceed 25 kW.

   (vi) The ERP for Class C1 stations must exceed 50 kW.

   (vii) The minimum ERP for Class C and C0 stations is 100 kW.

   (2) Class C0 stations must have an antenna height above average terrain
   (HAAT) of at least 300 meters (984 feet). Class C stations must have an
   antenna height above average terrain (HAAT) of at least 451 meters
   (1480 feet).

   (3) Stations of any class except Class A may have an ERP less than that
   specified in paragraph (a)(1) of this section, provided that the
   reference distance, determined in accordance with paragraph (b)(1)(i)
   of this section, exceeds the distance to the class contour for the next
   lower class. Class A stations may have an ERP less than 100 watts
   provided that the reference distance, determined in accordance with
   paragraph (b)(1)(i) of this section, equals or exceeds 6 kilometers.

   (b) Maximum limits. (1) Except for stations located in Puerto Rico or
   the Virgin Islands, the maximum ERP in any direction, reference HAAT,
   and distance to the class contour for each FM station class are listed
   below:
   Station class Maximum ERP Reference HAAT in meters (ft.) Class contour
   distance in kilometers
   A 6 kW (7.8 dBk) 100 (328) 28
   B1 25 kW (14.0 dBk) 100 (328) 39
   B 50 kW (17.0 dBk) 150 (492) 52
   C3 25 kW (14.0 dBk) 100 (328) 39
   C2 50 kW (17.0 dBk) 150 (492) 52
   C1 100 kW (20.0 dBk) 299 (981) 72
   C0 100 kW (20.0 dBk) 450 (1476) 83
   C 100 kW (20.0 dBk) 600 (1968) 92

   (i) The reference distance of a station is obtained by finding the
   predicted distance to the 1mV/m contour using Figure 1 of § 73.333 and
   then rounding to the nearest kilometer. Antenna HAAT is determined
   using the procedure in § 73.313. If the HAAT so determined is less than
   30 meters (100 feet), a HAAT of 30 meters must be used when finding the
   predicted distance to the 1 mV/m contour.

   (ii) If a station's ERP is equal to the maximum for its class, its
   antenna HAAT must not exceed the reference HAAT, regardless of the
   reference distance. For example, a Class A station operating with 6 kW
   ERP may have an antenna HAAT of 100 meters, but not 101 meters, even
   though the reference distance is 28 km in both cases.

   (iii) Except as provided in paragraph (b)(3) of this section, no
   station will be authorized in Zone I or I-A with an ERP equal to 50 kW
   and a HAAT exceeding 150 meters. No station will be authorized in Zone
   II with an ERP equal to 100 kW and a HAAT exceeding 600 meters.

   (2) If a station has an antenna HAAT greater than the reference HAAT
   for its class, its ERP must be lower than the class maximum such that
   the reference distance does not exceed the class contour distance. If
   the antenna HAAT is so great that the station's ERP must be lower than
   the minimum ERP for its class (specified in paragraphs (a)(1) and
   (a)(3) of this section), that lower ERP will become the minimum for
   that station.

   (3) For stations located in Puerto Rico or the Virgin Islands, the
   maximum ERP in any direction, reference HAAT, and distance to the class
   contour for each FM station class are listed below:
   Station class Maximum ERP Reference HAAT in meters (ft.) Class contour
   distance in kilometers
   A 6kW (7.8 dBk) 240 (787) 42
   B1 25kW (14.0 dBk) 150 (492) 46
   B 50kW (17.0 dBk) 472 (1549) 78

   (c) Existing stations. Stations authorized prior to March 1, 1984 that
   do not conform to the requirements of this section may continue to
   operate as authorized. Stations operating with facilities in excess of
   those specified in paragraph (b) of this section may not increase their
   effective radiated powers or extend their 1 mV/m field strength contour
   beyond the location permitted by their present authorizations. The
   provisions of this section will not apply to applications to increase
   facilities for those stations operating with less than the minimum
   power specified in paragraph (a) of this section.

   (d) Existing Class C stations below minimum antenna HAAT. Class C
   stations authorized prior to January 19, 2001 that do not meet the
   minimum antenna HAAT specified in paragraph (a)(2) of this section for
   Class C stations may continue to operate as authorized subject to the
   reclassification procedures set forth in Note 4 to § 73.3573.

   [ 53 FR 17042 , May 13, 1988, as amended at  54 FR 16367 , Apr. 24, 1989;
    54 FR 19374 , May 5, 1989;  54 FR 35339 , Aug. 25, 1989;  65 FR 79777 , Dec.
   20, 2000]

   return arrow Back to Top


Goto Section: 73.210 | 73.212

Goto Year: 2013 | 2015
CiteFind - See documents on FCC website that cite this rule

Want to support this service?
Thanks!

Report errors in this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public