FCC 80.859 Revised as of October 1, 2014
Goto Year:2013 |
2015
§ 80.859 Main power supply.
(a) The main power supply must simultaneously energize the
radiotelephone transmitter at its required antenna power and the
required receivers. Under this load condition the voltage of the main
power supply at the radiotelephone input terminals must not deviate
from its rated potential by more than 10 percent on ships completed on
or after July 1, 1941, nor by more than 15 percent on ships completed
before that date.
(b) Means must be provided for charging any batteries used as a main
power supply. A continuous indication of the rate and polarity of the
charging current must be provided during charging of the batteries.