Goto Section: 15.212 | 15.214 | Table of Contents

FCC 15.213
Revised as of October 1, 2013
Goto Year:2012 | 2014
§  15.213   Cable locating equipment.

   An intentional radiator used as cable locating equipment, as defined in
   §  15.3(d), may be operated on any frequency within the band 9-490 kHz,
   subject to the following limits: Within the frequency band 9 kHz, up
   to, but not including, 45 kHz, the peak output power from the cable
   locating equipment shall not exceed 10 watts; and, within the frequency
   band 45 kHz to 490 kHz, the peak output power from the cable locating
   equipment shall not exceed one watt. If provisions are made for
   connection of the cable locating equipment to the AC power lines, the
   conducted limits in §  15.207 also apply to this equipment.

   return arrow Back to Top


Goto Section: 15.212 | 15.214

Goto Year: 2012 | 2014
CiteFind - See documents on FCC website that cite this rule

Want to support this service?
Thanks!

Report errors in this rule. Since these rules are converted to HTML by machine, it's possible errors have been made. Please help us improve these rules by clicking the Report FCC Rule Errors link to report an error.
hallikainen.com
Helping make public information public